12015Jun 0 Urine hCG Test By Alissa Harris / CommentsOff Take the following 2017 Urine hCG Competency Test. You must score 80% on the competency test. The test can be taken multiple times until this score is reached. Type your first and last name in the Name field below. Click the Next button to start the test. Name 1. When should the Test Cassette be removed from the foil pouch?30 minutes before use1 hour before useJust before use2 hours before use2. When do Positive and Negative Controls need to be run on the kit?When do Positive and Negative Controls need to be run on the kit?Don't need to run controlsOnce every 20 testsDaily before the first test of the dayWith each new lot or shipment of test materials3. When performing patient or control testing, the current Package Insert instructions and/or Procedure Card should be followed for accurate results.TrueFalse4. What is interpreted as POSITIVE?Any pink-to-red Test Line (T) along with a blue Control Line (C)A pink-to-red Test Line (T) intersecting the blue Control Line (C)A blue Control Line (C) and no pink Test Line (T)A pink-to-red Test Line (T) and no blue Control Line (C)5. What is interpreted as NEGATIVE?Any pink-to-red Test Line (T) and a blue Control Line (C)A pink-to-red Test Line (T) and a blue Control Line (C)A blue Control Line (C) and no pink Test Line (T)A pink-to-red Test Line (T) and no blue Control Line (C)6. What is the read time for the kit?3 minutes5 minutes8 minutes10 minutes7. At what temperature do the kits and controls need to be stored?36-46 degrees F (refrigerated)59 - 86 degrees F (room temperature)-20 degrees C (frozen)The manufacturer doesn't have any storage recommendations8. How many drops of urine or control are needed to perform the test?5 drops4 drops3 drops2 drops9. When do Positive and Negative Controls need to be run on the kit?Don't need to run controlsOnce every 20 testsDaily before the first test of the dayWith each new lot or shipment of test materials10. If a blue Control Line (C) is not visible at 3 minutes, the test result is invalid and you should retest using a new sample and a new test Cassette.TrueFalse11. What is the detection level of this test?20 mIU/mL10 mIU/mL25 mIU/mL15 mIU/mL12. What is interpreted as POSITIVE?Any pink-to-red Test Line (T) along with a blue Control Line (C)A pink-to-red Test Line (T) intersecting the blue Control Line (C)A blue Control Line (C) and no pink Test Line (T)A pink-to-red Test Line (T) and no blue Control Line (C)Click Submit Quiz to see your results. A submission email will be sent to the designated OISC Administrator. If you would like a certificate of completion, let Alissa know and one can be printed for you. Time is Up!